Our Products
Other Security Equipment
- Bollards
|
Features & Specification :
Blocking Height |
1000 MM |
Blocking Dia |
300 MM |
Material |
Bollard pipe is made of high quality steel i.e Steel FE360 with zinc based plastic quoting |
Thickness of pipe: 15mm |
|
Impact Rate Load |
Certified to absorb- minimum kinetic energy of 610 KJ |
Wheel Load |
100kN according to SLW 60 - DIN 1072 |
Product Certification |
Individual bollard carry crash rating M-30 (K-4) as per DOS (USA) or PAS 68 K4 (UK) /ASTM for impact load from 6.8 ton truck at speed of 30mile per hr. |
Maximum level of vehicle Penetration |
3 Feet from bollard after impact (for each bollard) |
Operation Time: Normal use |
Raising: Approx 6 sec |
Lowering to road surface: Approx 3 Sec |
|
Operation time of bollards remain same from single unit to set of upto ten units. It does not increase in case of number of units is increased in a single set |
|
Lighting |
Bollards have red light reflector or indicator on top |
Power Failure |
Bollards remain in raised position in case of sudden power failure |
Drive Unit |
The drive unit is consisting of two hydraulic pumps with an integrated oil tank placed in the bollards framework. The hydraulic unit is a closed system without any external hydraulic tubes. The working principle of the hydraulic unit is to push the blocking element from the framework of the bollards via piston in the upper position. Manual release is possible via an access in the bollard head. |
Pressure Limit Valve (Operating Pressure) |
The pressure limit valve controls the operating pressure of the bollards |
Hydraulic Unit |
Compact hydraulic drive unit with aggregate, high pressure pump integrated in a drive cabinet. |
Control |
Control Unit - Raise - Stop - Lower |
Control Unit in drive cabinet,pre-wired in factory . |
|
Protection against Corrosion |
Long-term plastic against corrosion by zinc based multilayer plastic coating. The bollards have weatherproofing as per IP68 standard |
Hydraulic Pressure Unit |
Hydraulic Pressure Unit of the bollards is within the bollard |
Drive Cabinet |
It is inside the bollard casing for each bollard. |
Power |
220V AC /24V DC |
Maintenance Free |
System is maintenance free till minimum 100000 duty |
Operating Temperature |
Minimum. (-) 15°C Maximum (+) 55°C |
Type |
One master & slave units up to 9 for configuration for two, three or |
Electronic Control |
With micro processor & specific software for controlling bollards. |
Control Cabinet |
inside Security Control Room. |
Mounting |
Control Cabinet is easily wall mountable. |
Switch for Operation |
Push Button |
Features of control |
(a) Alarm |
Integration |
Control box have ports to integrate with any kind of access |
Master Control Unit |
Capable of controlling bollards set of maximum ten units, |